Link
https://aliexpress.ru/item/1005009188162330.html?sku_id=12000048239089509&spm=a2g2w.productlist.search_results.3.17f63cd6hSIB0x
Database entry
{"id":32,"type":"EndDevice","ieeeAddr":"0xa4c138423dc4b926","nwkAddr":57683,"manufId":4417,"manufName":"_TZE284_tz0bdogs","powerSource":"Battery","modelId":"TS0601","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[4,5,61184,0,60672],"outClusterList":[25,10],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":77,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{},"lastSeen":1779302379603}
Zigbee2MQTT version
2.11.0 (unknown)
External definition
export default {
zigbeeModel: ['TS0601'],
model: 'TS0601',
vendor: '_TZE284_tz0bdogs',
description: 'Automatically generated definition',
extend: [],
};
What does/doesn't work with the external definition?
Zigbee smart thermostatic radiator valve Model:1411zs
OUI: Telink Semiconductor (Taipei) Co. Ltd.
Platform
Core 2026.5.2
Supervisor 2026.05.0
Operation system HAOS 17.3
Logs of the issue (if applicable)
{"id":32,"type":"EndDevice","ieeeAddr":"0xa4c138423dc4b926","nwkAddr":57683,"manufId":4417,"manufName":"_TZE284_tz0bdogs","powerSource":"Battery","modelId":"TS0601","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[4,5,61184,0,60672],"outClusterList":[25,10],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":77,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{},"lastSeen":1779302379603}
Notes
software_build_id: undefined
date_code: ``
endpoints:
{"1":{"bindings":[],"clusters":{"input":["genGroups","genScenes","manuSpecificTuya","genBasic","60672"],"output":["genOta","genTime"]},"configured_reportings":[],"scenes":[]}}
Link
https://aliexpress.ru/item/1005009188162330.html?sku_id=12000048239089509&spm=a2g2w.productlist.search_results.3.17f63cd6hSIB0x
Database entry
{"id":32,"type":"EndDevice","ieeeAddr":"0xa4c138423dc4b926","nwkAddr":57683,"manufId":4417,"manufName":"_TZE284_tz0bdogs","powerSource":"Battery","modelId":"TS0601","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[4,5,61184,0,60672],"outClusterList":[25,10],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":77,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{},"lastSeen":1779302379603}
Zigbee2MQTT version
2.11.0 (unknown)
External definition
What does/doesn't work with the external definition?
Zigbee smart thermostatic radiator valve Model:1411zs
OUI: Telink Semiconductor (Taipei) Co. Ltd.
Platform
Core 2026.5.2
Supervisor 2026.05.0
Operation system HAOS 17.3
Logs of the issue (if applicable)
{"id":32,"type":"EndDevice","ieeeAddr":"0xa4c138423dc4b926","nwkAddr":57683,"manufId":4417,"manufName":"_TZE284_tz0bdogs","powerSource":"Battery","modelId":"TS0601","epList":[1],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[4,5,61184,0,60672],"outClusterList":[25,10],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":77,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{},"lastSeen":1779302379603}
Notes
software_build_id:
undefineddate_code: ``
endpoints:
{"1":{"bindings":[],"clusters":{"input":["genGroups","genScenes","manuSpecificTuya","genBasic","60672"],"output":["genOta","genTime"]},"configured_reportings":[],"scenes":[]}}