An RFSG device we added (NI-5650) could never be controlled by atticus. We tried multiple NI RFSG drivers (from 1.8.5 to 16.0) but the problem persisted (see error message below).
Our only workaround was to build atticus in the 32-bit version rather than the 64-bit.
1/15/2019 1:55:13 PM AtticusServer.AtticusServerCommunicator: Failed buffer generation due to exception: Caught exception when attempting to instantiate an rfsg device named RF1. Maybe a device by this name does not exist? Exception message: An attempt was made to load a program with an incorrect format. (Exception from HRESULT: 0x8007000B)
at AtticusServer.RfsgTask..ctor(SequenceData sequence, SettingsData settings, Int32 channelID, String rfsgDeviceName, DeviceSettings deviceSettings) in C:\Users\Fermi1\Desktop\CiceroAtticus\Cicero-Word-Generator-devel-1.7\Cicero-Word-Generator-devel-1.7\AtticusServer\ServerRuntime\RfsgTask.cs:line 238
at AtticusServer.AtticusServerCommunicator.generateBuffers(Int32 listIterationNumber) in C:\Users\Fermi1\Desktop\CiceroAtticus\Cicero-Word-Generator-devel-1.7\Cicero-Word-Generator-devel-1.7\AtticusServer\ServerRuntime\AtticusServerCommunicator.cs:line 816
An RFSG device we added (NI-5650) could never be controlled by atticus. We tried multiple NI RFSG drivers (from 1.8.5 to 16.0) but the problem persisted (see error message below).
Our only workaround was to build atticus in the 32-bit version rather than the 64-bit.
at AtticusServer.AtticusServerCommunicator.generateBuffers(Int32 listIterationNumber) in C:\Users\Fermi1\Desktop\CiceroAtticus\Cicero-Word-Generator-devel-1.7\Cicero-Word-Generator-devel-1.7\AtticusServer\ServerRuntime\AtticusServerCommunicator.cs:line 816