HP Smart Array CLI
https://blog.sleeplessbeastie.eu/2017/03/06/how-to-use-hp-command-line-array-configuration-utility/
Disk Status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show status
Disk Details
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show detail
Logical Drive Status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld all show status
Logical Drive Details
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 show
Controller Details
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show detail
Modify Cache Ratio
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify cr=25/75
PSSC MegaCLi
Virtual Drive
MegaCli64 -LDInfo -Lall -aALL
Physical Drive
MegaCli64 -PDList -aALL
Dump all info
sudo /opt/MegaRAID/MegaCli/MegaCli64 -AdpAllInfo -aALL
Softlayer
Show summary of controller, Virtual and Physical drive info
/opt/MegaRAID/storcli/storcli64 /c0 show