Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathsimulation_code.m
More file actions
106 lines (92 loc) · 5.36 KB
/
simulation_code.m
File metadata and controls
106 lines (92 loc) · 5.36 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
mdl = 'simulation.slx';
blockName = 'simulation/Three-Phase Fault';
%open(mdl)
fault_length = linspace(20 * 0.01, 20 * 0.99, 100);
fault_length1 = fault_length(1:20); %DONE, PRUNE
fault_length1 = fault_length1([5:9, 12:20]);
fault_length2 = fault_length(21:40); %ALI PC, DONE 21:30
fault_length3 = fault_length(41:60); %JOHN PC, DONE 41:50
fault_length4 = fault_length(61:80); %NATHAN PC, DONE 61:70
fault_length5 = fault_length(81:100); %SENNE PC, need 81,90,89,88
%ALSO PRUNE TOMORROW AND MAKE SURE STARTING FROM CORRECT I
fault_resistance = [5, 10, 15, 20, 25, 30, 40, 50];
fault_inception_time = linspace(0.004, 0.024, 6) + 0.02 ;
%fault_inception_time_end = fault_inception_time + 1/50;
Rburden = 100;
fault_types = ["AG", "BG", "CG", "AB", "AC", "BC", "ABG", "ACG", "BCG", "ABCG", "NOFAULT"];
len_fault_length = length(fault_length1);
len_fault_resistance = length(fault_resistance);
len_fault_inception_time = length(fault_inception_time);
len_fault_types = length(fault_types);
simulationResults = cell(len_fault_resistance, len_fault_inception_time, len_fault_types);
%open_system('simulation.slx');
%sim('simulation.slx'); % To get timestamps (if needed)
% t_in = ans.tout;
%get_param('simulation/Three-Phase Fault1','DialogParameters')
%get_param('simulation/Three-Phase Fault','SwitchTimes')
%tic
for i = 1:len_fault_length
fault_length_val = fault_length1(i);
set_param('simulation/Line','Length', num2str(fault_length_val));
set_param('simulation/Line 2','Length', num2str(20 - fault_length_val));
for j = 1:len_fault_resistance
fault_resistance_val = fault_resistance(j);
set_param('simulation/Three-Phase Fault', 'FaultResistance', num2str(fault_resistance_val));
for z = 1:len_fault_inception_time
fault_time_val = fault_inception_time(z); %start fault after 5 cycles
%fault_time_end = fault_inception_time_end(z);
start = num2str(fault_time_val);
% stop = num2str(fault_time_end);
formatted_string = ['[', start, ']'];
set_param('simulation/Three-Phase Fault' ,'SwitchTimes', formatted_string);
for y = 1:len_fault_types
%tic
fault_type_val = fault_types(y);
% Set fault parameters in Simulink model
% Check the current fault type and set parameters accordingly
if strcmp(fault_type_val, 'AG')
% Set the checkbox on/off
set_param(blockName, 'FaultA', 'on', 'FaultB', 'off', 'FaultC', 'off', 'GroundFault', 'on');
elseif strcmp(fault_type_val, 'BG')
set_param(blockName, 'FaultA', 'off', 'FaultB', 'on', 'FaultC', 'off', 'GroundFault', 'on');
elseif strcmp(fault_type_val, 'CG')
set_param(blockName, 'FaultA', 'off', 'FaultB', 'off', 'FaultC', 'on', 'GroundFault', 'on');
elseif strcmp(fault_type_val, 'AB')
set_param(blockName, 'FaultA', 'on', 'FaultB', 'on', 'FaultC', 'off', 'GroundFault', 'off');
elseif strcmp(fault_type_val, 'AC')
set_param(blockName, 'FaultA', 'on', 'FaultB', 'off', 'FaultC', 'on', 'GroundFault', 'off');
elseif strcmp(fault_type_val, 'BC')
set_param(blockName, 'FaultA', 'off', 'FaultB', 'on', 'FaultC', 'on', 'GroundFault', 'off');
elseif strcmp(fault_type_val, 'ABG')
set_param(blockName, 'FaultA', 'on', 'FaultB', 'on', 'FaultC', 'off', 'GroundFault', 'on');
elseif strcmp(fault_type_val, 'ACG')
set_param(blockName, 'FaultA', 'on', 'FaultB', 'off', 'FaultC', 'on', 'GroundFault', 'on');
elseif strcmp(fault_type_val, 'BCG')
set_param(blockName, 'FaultA', 'off', 'FaultB', 'on', 'FaultC', 'on', 'GroundFault', 'on');
elseif strcmp(fault_type_val, 'ABCG')
set_param(blockName, 'FaultA', 'on', 'FaultB', 'on', 'FaultC', 'on', 'GroundFault', 'on');
elseif strcmp(fault_type_val, 'NOFAULT')
set_param(blockName, 'FaultA', 'off', 'FaultB', 'off', 'FaultC', 'off', 'GroundFault', 'off');
end
% Run simulation
sim('simulation.slx');
%Simulate voltage waveform calculation using measurement CT
%Vabc = (5/1.2e3)*ans.Iabc.Data*Rburden+1.65; %including DC offset
%Vabc2 = (5/1.2e3)*ans.Iabc2.Data*Rburden+1.65;
% Save simulation results
simulationResults{j, z, y} = [ans.Iabc.Data , ans.Iabc2.Data];
%results(i,j,z,y,:) = [ans.Iabc.Data , ans.Iabc2.Data];
% w = simulationResults{1,1,1,1};
%toc
if y == 11 && z == 6 && j == 8
varName = num2str(i);
filename = sprintf('result0_%d.mat', i);
% filename = simulationResults{i,:,:,:};
newsave = pruner(simulationResults);
save(filename,"newsave"','-v7.3')
simulationResults = cell(len_fault_resistance, len_fault_inception_time, len_fault_types);
end
end
end
end
end