Ventilation Controller CC

A custom Home Assistant component that automatically controls your Ramses RF ventilation unit based on real-time air quality measurements. The controller uses air quality sensors to calculate an index from 0 (excellent) to 5 (very poor) and adjusts fan speed accordingly.

Supported Sensor Types:

  • CO2 (Carbon Dioxide)
  • PM (Particulate Matter - PM1.0, PM2.5, PM10)
  • VOC (Volatile Organic Compounds)
  • Humidity

Need support for other sensor types? Feel free to open an issue on GitHub!

The controller supports multi-zone systems by mimicking a CO2 sensor for each zone, without interfering with existing sensors already bound to your ventilation box or zone controller. The current version uses fake remote devices to send commands to your ventilation system.

Prerequisites: This guide assumes you have already configured Ramses CC integration with a working remote device in Home Assistant.

How to Use

Step 1: Configure Ramses CC

Add the number of faked CO2 devices to your Ramses CC's "known devices" section equal to the number of zones in your ventilation system. Use device IDs that are logical. E.g., check your actual CO2 sensor's ID, and increment the last number for each zone. In the example below you see how I have one actual sensor, and two fake ones where I simply incremented the last digit. These sensors will later be used to send fan commands based on the current air quality.

"29:181232":
  class: CO2
"29:181233":
  class: CO2
  faked: true
"29:181234":
  class: CO2
  faked: true

Step 2: Install the Integration

Option A: Via Home Assistant Community Store (HACS) - Recommended

  1. Make sure you have HACS installed in your Home Assistant
  2. In Home Assistant, go to HACSIntegrations
  3. Click the menu (three dots) in the top right corner
  4. Select Custom repositories
  5. Add the repository URL: https://github.com/IMMRMKW/Ventilation_controller_cc
  6. Select Integration as the category
  7. Click Add
  8. Find "PID Ventilation Control" in the HACS integrations list and click Download
  9. Restart Home Assistant after the download completes

Option B: Manual Installation

  1. Navigate to your Home Assistant custom_components folder
  2. Copy+Paste the folder called ventilation of this repository into your custom_components folder
  3. Restart Home Assistant

Step 3: Configure the Integration

  1. Go to SettingsDevices & ServicesAdd Integration
  2. Search for "PID Ventilation Control" and select it
  3. Follow the configuration steps:

Remote selection and zone number

In the dropdown menus, select your remote controller and the number of zones your system uses. If you do not have a zone controller and have one ventilation unit, set zones to 1.

Fan settings

Zone Configuration

For each zone in your system, you'll configure the device communication and fan control settings:

  • From Device (Source): Select one of the fake CO2 sensor(s) that you previously created in your known devices list. Each fake sensor will act as if present in one of the zones.
  • To Device (Target): Select the fan controller or valve device for this specific zone
  • Sensor ID: Identifier used in messages (defaults to 255 for zone 1, 254 for zone 2, etc.). This variable modifies the ramses rf message. Leave as is.
  • Min/Max Fan Rate: Control the fan speed range for this zone (0-255)

Zone device configuration

Sensor Types

Select which types of air quality sensors you want to use. Toggle "back" and submit to return to the previous step.

Sensor types

Sensor Selection

Choose the specific sensor entities for each selected sensor type.

CO2 sensor selection

Sensor Zone Assignment

If you have multiple zones, assign each sensor to the zone it monitors. This allows the controller to adjust fan speeds independently for each zone based on local air quality conditions.

Sensor zone assignment

Air Quality Index Configuration

This step defines how sensor readings are converted to air quality indices (0-5). The controller uses the highest index from all sensors as the overall air quality.

For example, CO2 values:

  • 400-650 ppm = Index 0 (excellent)
  • 650-1500 ppm = Index 1 (good)
  • And so on...

The default values are based on health guidelines and should work well for most setups. You can adjust them later if needed.

Air quality index thresholds

PID Controller Settings

Configure the control algorithm parameters:

  • Setpoint: Target air quality index (1.2 is a good starting point for CO2)
  • Proportional Gain (Kp): How the fan power linearly increases with increasing deviation of the air quality compared to your setpoint
  • Integral Gain (Ki): Six values controlling response time for each air quality level (represents approximate time to reach 100% fan speed). You can use the six numbers so the controller responds differently when the air quality is already quite good (index = 0) compared to when the air quality is poor (index = 5)
  • Update Interval: How often to check sensors and adjust the fan (in seconds)

Note: Many ventilation systems only adjust every 10 minutes, so very short intervals may not improve responsiveness.

PID controller parameters

Step 4: Bind Sensors

Before the system will work, your ventilation box or zone controller must accept commands from the fake sensors you defined in Step 1. This requires a one-time binding process:

  1. Enable Pairing Mode: Ensure your ventilation unit or zone controller is in pairing mode. Many systems automatically enter pairing mode for the first few minutes after startup, so a simple power cycle is usually sufficient.

  2. Execute Binding Functions: In Home Assistant, navigate to Developer ToolsActions. In the search bar, type "bind" and you'll find one binding function for each zone you configured (as shown in the image below).

  3. Perform Binding: Execute each binding function once by selecting it and clicking Perform Action. Do this for all configured zones.

  4. Verify Success: After binding, your system should accept messages from the fake sensors. You can confirm successful binding by checking the Ramses CC log file for message exchanges during the binding process.

Binding functions in Developer Tools

Step 5: Setup Complete

After completing all configuration steps, your ventilation controller is ready! The integration will:

  1. Monitor your selected air quality sensors continuously
  2. Calculate an overall air quality index (0-5) for each zone
  3. Control fan speeds automatically using the PID algorithm
  4. Adjust each zone independently based on local sensor readings

You can monitor and adjust the system through:

  • SettingsDevices & ServicesPID Ventilation Control (to reconfigure)
  • Developer ToolsStates (to see current sensor values and fan outputs)

About

A custom component for Home Assistant that allows the remote controller of your Ramses RF setup to continually send ventilations commands to your ventilation unit based on the current air quality in your house. The air quality is a number from 0 to 5, and is based on various sensors that you can add to the controller.