Dominance of waste CHP plants in district heating mixes #60

Description

@cpschau

Checklist

  • I am using the current master branch or the latest release. Please indicate.
  • I am running on an up-to-date pypsa-eur environment. Update via conda env update -f envs/environment.yaml.

Describe the Issue

The district heating supply mix is dominated by waste CHP plants that burn the non-sequestered HVC from naphtha production. This result was obtained using the default pypsa-de configuration (without biogenic municipal solid waste, but waste_to_energy turned to true) at a 9h-resolution & 27-cluster-resolution for "KN2045_Bal_v4".

Image

Image

2020 mix according to AGFW:

Image