Wenhui and I noticed this while discussing a few papers that implemented a high NA version of ptychography.

In the original propagator for high NA light, I neglected to include the factor of 1/r^2 due to the edges of the detector being further from the sample than the center of the detector, and I only included the factor of cos(theta) which deals with the angle of incidence of the radiation.

It's a small correction but it seems to be meaningful when testing it on some high NA data.

Copy link
Collaborator

@yoshikisd yoshikisd left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Looks good to me

@yoshikisd yoshikisd merged commit ca3c48e into master Feb 11, 2026
9 checks passed
@yoshikisd yoshikisd deleted the new_high_NA_intensity branch February 11, 2026 17:41