A research-grade framework for evaluating compression algorithms in High Energy Physics (HEP) workflows with integrated energy consumption and carbon footprint analysis.
Modern High Energy Physics (HEP) experiments generate petabyte-scale datasets. While compression reduces storage requirements, it introduces computational overhead that consumes energy and produces carbon emissions.
This project provides a reproducible benchmarking framework that evaluates:
- Binary compression algorithms (gzip, lzma, zstd)
- Delta encoding pre-processing
- ROOT internal compression levels
- CPU energy consumption during compression/decompression
- Long-term storage energy costs
- Total carbon footprint impact
The goal is to determine whether compression strategies reduce overall environmental impact when both compute and storage energy are considered.
Large-scale experiments such as those conducted at facilities like CERN rely heavily on ROOT-based data formats and multi-year storage infrastructures.
Sustainability in scientific computing is becoming a critical concern. Compression is typically evaluated only by:
- Compression ratio
- Throughput
- Decompression speed
This framework extends evaluation to include:
- Energy consumption (kWh)
- Storage lifetime energy cost
- CO₂ emissions (kg)
This enables environmentally-aware optimization of data pipelines.
-
Simulates particle collision events
-
Stores raw binary datasets
-
Applies delta encoding
-
Benchmarks:
- gzip
- lzma
- zstd
-
Generates ROOT files with configurable compression levels
-
Measures:
- Compression time
- Decompression time
- File size
- Total energy consumption
- Carbon emissions
-
Exports results to CSV
-
Produces comparative energy visualization plots
- Monte Carlo particle event generation
- Delta encoding implementation
- ROOT TTree generation with configurable compression levels
- Energy consumption modeling
- Carbon emission estimation
- Automatic benchmarking
- CSV export of results
- Energy comparison visualization
Total energy is calculated as:
Total Energy = CPU Energy (compression + decompression)
- Storage Energy (multi-year retention)
Carbon emissions are computed as:
CO₂ = Energy × Carbon Intensity
Parameters such as CPU power, storage intensity, and retention period are configurable.
git clone https://github.com/lynashere/GreenHEP-Compression.git
cd GreenHEP-Compression
pip install -r requirements.txtTo install the GreenHEP package, add :
pip install .python main.py- Sustainable computing in High Energy Physics
- Green data center optimization
- Compression-energy tradeoff analysis
- Computational research
- Infrastructure carbon auditing
- Parallel compression benchmarking
- GPU compression comparison
- Real experimental datasets
- Distributed storage modeling
- Life-cycle analysis of scientific data pipelines