6 changes: 4 additions & 2 deletions net/nut/Makefile
Original file line number Diff line number Diff line change
Expand Up @@ -9,7 +9,7 @@ include $(TOPDIR)/rules.mk

PKG_NAME:=nut
PKG_VERSION:=2.8.4
PKG_RELEASE:=2
PKG_RELEASE:=3

PKG_SOURCE:=$(PKG_NAME)-$(PKG_VERSION).tar.gz
PKG_SOURCE_URL:=https://www.networkupstools.org/source/2.8/
Expand All @@ -18,6 +18,8 @@ PKG_LICENSE:=GPL-2.0-or-later GPL-3.0-or-later GPL-1.0-or-later Artistic-1.0-Per
PKG_LICENSE_FILES:=LICENSE-GPL2 LICENSE-GPL3 COPYING
PKG_FIXUP:=autoreconf

PKG_MAINTAINER:=Daniel F. Dickinson <dfdpublic@wildtechgarden.ca>

PKG_INSTALL:=1

PKG_CONFIG_DEPENDS:= \
Expand Down Expand Up @@ -156,7 +158,7 @@ part of UPS monitoring--shutting down the system when the power goes
out. It can call out to other helper programs for notification purposes
during power events. upsmon can monitor multiple systems using a single
process. Every UPS that is defined in the upsmon.conf configuration file
is assigned a power value and a type (slave or master).
is assigned a power value and a type (secondary or primary).
endef

define Package/nut-upsmon/conffiles
Expand Down
170 changes: 82 additions & 88 deletions net/nut/files/nut-monitor.init
100755 → 100644
Original file line number Diff line number Diff line change
Expand Up @@ -9,118 +9,106 @@ USE_PROCD=1
UPSMON_C=/var/etc/nut/upsmon.conf
PIDFILE=/var/run/upsmon.pid

# Upstream NUT event type names (in the order listed in
# https://networkupstools.org/docs/man/upsmon.conf.html)
NUT_EVENT_TYPES=" ONLINE ONBATT LOWBATT FSD COMMOK COMMBAD SHUTDOWN REPLBATT NOCOMM NOPARENT CAL NOTCAL OFF NOTOFF BYPASS NOTBYPASS ECO NOTECO OVER NOTOVER TRIM NOTTRIM BOOST NOTBOOST OTHER NOTOTHER SUSPEND_STARTING SUSPEND_FINISHED "

nut_get_notifications() {
local event="$1"
local defaultnotify="$2"

if [ "${NUT_EVENT_TYPES#*" $event "}" != "${NUT_EVENT_TYPES}" ]; then
config_get val "$event" message
[ -n "$val" ] && echo "NOTIFYMSG $event \"$val\"" >>"$UPSMON_C"
config_get val "$event" flag "$defaultnotify"
[ -n "$val" ] && echo "NOTIFYFLAG $event $val" >>"$UPSMON_C"
else
logger -t nut-monitor -s "$event is not a valid NUT message event type"
fi
}

nut_upsmon_conf() {
local cfg="$1"
local RUNAS val optval
local RUNAS val optval defaultnotify

echo "# Config file automatically generated from UCI config" > "$UPSMON_C"
echo "# Config file automatically generated from UCI config" >"$UPSMON_C"

config_get RUNAS "$cfg" runas "nutmon"
[ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >> "$UPSMON_C"
[ -n "$RUNAS" ] && echo "RUN_AS_USER $RUNAS" >>"$UPSMON_C"
runas="$RUNAS"

config_get val "$cfg" deadtime 15
echo "DEADTIME $val" >>"$UPSMON_C"

config_get val "$cfg" finaldelay 5
echo "FINALDELAY $val" >>"$UPSMON_C"

config_get val "$cfg" hostsync 15
echo "HOSTSYNC $val" >>"$UPSMON_C"

config_get val "$cfg" minsupplies 1
echo "MINSUPPLIES $val" >> "$UPSMON_C"
echo "MINSUPPLIES $val" >>"$UPSMON_C"

config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
echo "SHUTDOWNCMD \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" nocommwarntime 300
echo "NOCOMMWARNTIME $val" >>"$UPSMON_C"

config_get val "$cfg" pollfaillogthrottlemax 1
echo "POLLFAIL_LOG_THROTTLE_MAX $val" >>"$UPSMON_C"

config_get val "$cfg" notifycmd
[ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >> "$UPSMON_C"
[ -n "$val" ] && echo "NOTIFYCMD \"$val\"" >>"$UPSMON_C"

config_get val "$cfg" pollfreq 5
echo "POLLFREQ $val" >> "$UPSMON_C"
echo "POLLFREQ $val" >>"$UPSMON_C"

config_get val "$cfg" pollfreqalert 5
echo "POLLFREQALERT $val" >> "$UPSMON_C"
echo "POLLFREQALERT $val" >>"$UPSMON_C"

config_get val "$cfg" hostsync 15
echo "HOSTSYNC $val" >> "$UPSMON_C"
echo "POWERDOWNFLAG /var/run/killpower" >>"$UPSMON_C"

config_get val "$cfg" deadtime 15
echo "DEADTIME $val" >> "$UPSMON_C"

echo "POWERDOWNFLAG /var/run/killpower" >> "$UPSMON_C"

config_get val "$cfg" onlinemsg
[ -n "$val" ] && echo "NOTIFYMSG ONLINE \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" onbattmsg
[ -n "$val" ] && echo "NOTIFYMSG ONBATT \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" lowbattmsg
[ -n "$val" ] && echo "NOTIFYMSG LOWBATT \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" fsdmsg
[ -n "$val" ] && echo "NOTIFYMSG FSD \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" commokmsg
[ -n "$val" ] && echo "NOTIFYMSG COMMOK \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" commbadmsg
[ -n "$val" ] && echo "NOTIFYMSG COMMBAD \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" shutdownmsg
[ -n "$val" ] && echo "NOTIFYMSG SHUTDOWN \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" replbattmsg
[ -n "$val" ] && echo "NOTIFYMSG REPLBATT \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" nocommmsg
[ -n "$val" ] && echo "NOTIFYMSG NOCOMM \"$val\"" >> "$UPSMON_C"
config_get val "$cfg" noparentmsg
[ -n "$val" ] && echo "NOTIFYMSG NOPARENT \"$val\"" >> "$UPSMON_C"

notifylist() {
local value="$1"
append optval "$value" "+"
}
config_get val "$cfg" offduration 30
echo "OFFDURATION $val" >>"$UPSMON_C"

setnotify() {
local cfg="$1"
local optname="$2"
local optval
config_list_foreach "$cfg" "$optname" notifylist
if [ -z "$optval" ]; then
# If no list fallback to trying option, fallback to default
config_get optval "$cfg" "$optname" "$default"
if [ -n "$optval" ]; then
echo "$optval"
else
# No default, so do the NUT default
echo "SYSLOG"
fi
else
echo "$optval"
fi
}

local default optval
val=""
config_list_foreach "$cfg" defaultnotify notifylist
default="$optval"
{
echo "NOTIFYFLAG ONLINE $(setnotify "$cfg" onlinenotify)" ; \
echo "NOTIFYFLAG ONBATT $(setnotify "$cfg" onbattnotify)" ; \
echo "NOTIFYFLAG LOWBATT $(setnotify "$cfg" lowbatnotify)" ; \
echo "NOTIFYFLAG FSD $(setnotify "$cfg" fsdnotify)" ; \
echo "NOTIFYFLAG COMMOK $(setnotify "$cfg" commoknotify)" ; \
echo "NOTIFYFLAG COMMBAD $(setnotify "$cfg" commbadnotify)" ; \
echo "NOTIFYFLAG SHUTDOWN $(setnotify "$cfg" shutdownnotify)" ; \
echo "NOTIFYFLAG REPLBATT $(setnotify "$cfg" replbattnotify)" ; \
echo "NOTIFYFLAG NOCOMM $(setnotify "$cfg" nocommnotify)" ; \
echo "NOTIFYFLAG NOPARENT $(setnotify "$cfg" noparentnotify)" ; \
} >> "$UPSMON_C"
config_get val "$cfg" offduration -1
echo "OVERDURATION $val" >>"$UPSMON_C"

config_get val "$cfg" oblbduration 0
echo "OBLBDURATION $val" >>"$UPSMON_C"

config_get val "$cfg" rbwarntime 43200
echo "RBWARNTIME $val" >> "$UPSMON_C"
echo "RBWARNTIME $val" >>"$UPSMON_C"

config_get val "$cfg" nocommwarntime 300
echo "NOCOMMWARNTIME $val" >> "$UPSMON_C"
config_get val "$cfg" alarmcritical 1
echo "ALARMCRITICAL $val" >>"$UPSMON_C"

config_get val "$cfg" finaldelay 5
echo "FINALDELAY $val" >> "$UPSMON_C"
config_get val "$cfg" shutdownexit 0
echo "SHUTDOWNEXIT $val" >>"$UPSMON_C"

config_get val "$cfg" shutdowncmd "/usr/sbin/nutshutdown"
echo "SHUTDOWNCMD \"$val\"" >>"$UPSMON_C"

config_get val "$cfg" certpath
if [ -n "$val" ]; then echo "CERTPATH $val" >> "$UPSMON_C"; fi
if [ -n "$val" ]; then echo "CERTPATH $val" >>"$UPSMON_C"; fi

config_get_bool val "$cfg" certverify 0
if [ -n "$val" ]; then echo "CERTVERIFY $val" >> "$UPSMON_C"; fi
if [ -n "$val" ]; then echo "CERTVERIFY $val" >>"$UPSMON_C"; fi

config_get_bool val "$cfg" forcessl 0
if [ -n "$val" ]; then echo "FORCESSL $val" >> "$UPSMON_C"; fi
if [ -n "$val" ]; then echo "FORCESSL $val" >>"$UPSMON_C"; fi

config_get_bool val "$cfg" debugmin 0
if [ -n "$val" ]; then echo "DEBUG_MIN $val" >>"$UPSMON_C"; fi

config_get val "$cfg" defaultnotify "SYSLOG"
defaultnotify="$val"
config_foreach nut_get_notifications notifications "$val"

# Otherwise the default is WALL+SYSLOG
for event in $NUT_EVENT_TYPES; do
if ! grep -q "NOTIFYFLAG $event" "$UPSMON_C"; then
echo "NOTIFYFLAG $event $defaultnotify" >>"$UPSMON_C"
fi
done

havemon=1
}
Expand All @@ -142,11 +130,13 @@ nut_upsmon_add() {
config_get powervalue "$cfg" powervalue 1
config_get username "$cfg" username
config_get password "$cfg" password
config_get type "$cfg" type "${type:-secondary}"

system="$upsname@$hostname"
if [ -n "$port" ]; then
system="$system:$port";
system="$system:$port"
fi
echo "MONITOR $system $powervalue $username $password $type" >> "$UPSMON_C"
echo "MONITOR $system $powervalue $username $password $type" >>"$UPSMON_C"

havems=1
}
Expand All @@ -157,8 +147,12 @@ build_config() {

config_load nut_monitor
config_foreach nut_upsmon_conf upsmon
config_foreach nut_upsmon_add master master
config_foreach nut_upsmon_add slave slave
config_foreach nut_upsmon_add primary primary
config_foreach nut_upsmon_add secondary secondary
config_foreach nut_upsmon_add monitor
# master and slave are legacy section names. Prefer monitor.
config_foreach nut_upsmon_add master primary
config_foreach nut_upsmon_add slave secondary

[ ! -s /var/etc/nut/nut.conf ] && {
echo "MODE=netclient" >>/var/etc/nut/nut.conf
Expand Down
14 changes: 9 additions & 5 deletions net/nut/files/nut-sendmail-notify.default
Original file line number Diff line number Diff line change
Expand Up @@ -34,11 +34,15 @@ if [ "$REMOVEDEFAULTNOTIFY" = "1" ]; then
fi

if [ "$SKIPADDEXEC" != "1" ]; then
uci add_list nut_monitor.@upsmon[-1].defaultnotify="EXEC"
fi

if [ "$SKIPADDSYSLOG" != "1" ]; then
uci add_list nut_monitor.@upsmon[-1].defaultnotify="SYSLOG"
if [ "$SKIPADDSYSLOG" != "1" ]; then
uci set nut_monitor.@upsmon[-1].defaultnotify="SYSLOG+EXEC"
else
uci set nut_monitor.@upsmon[-1].defaultnotify="EXEC"
fi
else
if [ "$SKIPADDSYSLOG" != "1" ]; then
uci set nut_monitor.@upsmon[-1].defaultnotify="SYSLOG"
fi
fi

uci commit nut_monitor
65 changes: 35 additions & 30 deletions net/nut/files/nut_monitor
Original file line number Diff line number Diff line change
@@ -1,52 +1,57 @@
#config upsmon 'upsmon'
# option runas nutmon
# option deadtime 15
# option finaldelay 5 # final delay
# option hostsync 15
# option minsupplies 1
# option shutdowncmd '/usr/sbin/nutshutdown'
# option notifycmd /path/to/cmd
# list defaultnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# option nocommwarntime 300 # no communications warn time
# option pollfaillogthrottlemax -1
# option notifycmd '/path/to/cmd'
# option pollfreq 5
# option pollfreqalert 5
# option hostsync 15
# option deadtime 15
# option onlinemsg "online message"
# option onbattmsg "on battery message"
# option lowbattmsg "low battery message"
# option fsdmsg "forced shutdown message"
# option comokmsg "communications restored message"
# option combadmsg "communications bad message"
# option shutdowmsg "shutdown message"
# option replbattmsg "replace battery message"
# option nocommmsg "no communications message"
# option noparentmsg "no parent message"
# list onlinenotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list onbattnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list lowbattnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list fsdnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list comoknotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list combadnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list shutdownotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list replbattnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list nocommnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# list noparentnotify SYSLOG # can be SYSLOG or EXEC or IGNORE
# option rbwarntime 4200 # replace battery warn time
# option nocommwarntime 300 # no communications warn time
# option finaldelay 5 # final delay
# option offduration 30
# option overduration -1
# option oblbduration 0
# option shutdowncmd '/usr/sbin/nutshutdown'
# option rbwarntime 43200 # replace battery warn time
# option alarmcritical 1
# option shutdownexit 0
# option certpath /path/to/ca/dir
# option certverify 0
# option forcessl 0
# option debugmin 0
# option defaultnotify SYSLOG

#config master
#config monitor
# option type primary
# option upsname upsname
# option hostname localhost
# option port # optional port number
# option powervalue 1
# option username upsuser
# option password upspassword

#config slave
#config monitor
# option type secondary
# option upsname upsname
# option hostname localhost
# option port # optional port number
# option powervalue 1
# option username upsuser
# option password upspassword

#config notifications 'COMMOK'
# option message "Communications with UPS %s established"
# option flag "SYSLOG"

#config notifications 'COMMBAD'
# option message "Communications with UPS %s lost"
# option flag "SYSLOG+EXEC"

#config notifications 'ONLINE'
# option message "UPS %s is on line power"
# option flag "SYSLOG"

#config notifications 'ONBATT'
# option message "UPS %s is on battery power"
# option flag "SYSLOG+EXEC"
2 changes: 1 addition & 1 deletion net/nut/files/nut_server
Original file line number Diff line number Diff line change
Expand Up @@ -11,7 +11,7 @@
# option password upspassword
# option actions optional-action
# list instcmd optional-instant-command
# option upsmon slave|master
# option upsmon secondary|primary

#config listen_address
# option address ::1
Expand Down