A battery diagnostic that knows what it can't see.
AstraCell is a research-grade Python package for a question most battery diagnostics skip: is this fault identifiable from the telemetry that actually exists? It combines a first-principles battery-pack model with Fisher information, Cramér-Rao bounds, model-bias gating, and counterfactual experiment design. When the evidence is insufficient, it refuses to diagnose - then computes which sensor or excitation would make the question answerable.
The interesting result is not a higher classifier score. It is an auditable boundary between what the system can infer and what it must leave unknown.
| Area | Evidence in this repository |
|---|---|
| Numerical methods | FIM/CRLB observability analysis, VIF-based isolation, structural-bias estimation, Monte Carlo calibration |
| Verification | 256 tests covering physics invariants, property-based cases, regression findings, optional dependencies, and notebook integrity |
| Independent challenge | Synthetic self-consistency, PyBaMM external simulation, positive controls, and all eight cells in the Oxford degradation dataset |
| Software quality | Typed src/ package, Ruff formatting/linting, mypy, multi-version CI, reproducible examples, and executed notebooks |
| Research discipline | Claims-to-evidence ledger, pre-registered hypotheses, documented negative results, and explicit limitations |
Start here: five-minute portfolio · technical report · claims and evidence · reproduce the results · what failed
⚠️ ReadLIMITATIONS.mdbefore believing any number here. The OCV curves are stand-ins, not fitted cells. Nothing in this repository has ever detected a real fault, or touched a real battery. Every bound below is a statement about this model, validated against itself and against an external simulator - never against a cell.
A production BMS does not measure what you want to diagnose.
| Quantity | Real coverage | Consequence |
|---|---|---|
| Cell voltage | one per cell, ~1 mV | per-cell voltage faults are identifiable |
| Temperature | 4-12 sensors for ~96 cells, ±0.5-1 K | per-cell thermal faults mostly are not |
| Current | pack-level only, one shunt | per-cell current is inferred, never measured |
So "highlight the faulty cell on a 3D pack map" is, for thermal faults, undecidable from real telemetry. Most battery-diagnostic projects do it anyway.
AstraCell instead computes the Fisher information matrix of the pack's parameters under the actual sensor topology, and the Cramér-Rao lower bound it implies. The CRLB bounds the variance of every unbiased estimator - not of one algorithm. If it says a 40% cooling fault sits at 1.2σ, no detector you write will find it, and the honest thing to render is grey.
There is no fault classifier here, deliberately. A classifier answers "which fault?". AstraCell answers the logically prior question: "is that question answerable?" Building the classifier first produces a system that is confident exactly where it should be silent.
A second, sharper claim runs through everything: more data can make a structurally wrong answer more certain. A model wrong in a way the data cannot expose grows more confident as you feed it more samples - so AstraCell prices its own model bias and refuses when that bias dwarfs the signal.
The grey cells are not painted by a distance-to-sensor rule. They fall out of the Cramér-Rao bound.
The distinction this project is organised around. A result at one tier never licenses a claim at a higher one.
| Tier | Meaning | Where AstraCell stands |
|---|---|---|
| 1 - internal self-consistency and synthetic experiments | Within AstraCell's own models, plus theorems about the estimator | Extensive |
| 2 - independently developed external simulator | Against PyBaMM, a simulator AstraCell did not implement | The phantom-fault refusal and the positive control |
| 3 - physical battery validation | A measured cell, a real fault | Contact, not validation. v0.7 ran all eight cells: the ECM is directionally wrong on every one and AstraCell refuses all 208 evaluations; v0.8 confirmed the refusal survives a second-order observer (0/208 verdicts change), and v0.9 that fitting the fast RC branch is inert on it too (1/208, H1 falsified - the branch is unidentifiable from a 1C discharge) (REAL_CELL) - eight cells, not validation |
Produced by python examples/01_first_demo.py on a 4×8 pack (32 cells, 32 voltage
channels, 4 thermocouples, 1 current shunt), 1200 s of 1.0C pulse excitation, 1 mV / 0.5 K
noise. These numbers assume white noise and a known current - both are relaxed in the
report, and one headline verdict flips when they are.
| Fault hypothesis | Thermocouple? | CRLB (1σ) | SNR | Verdict |
|---|---|---|---|---|
R0 +20% on cell 5 |
no | ±0.13% | 149.2σ | DIAGNOSE |
| capacity −5% on cell 17 | no | ±0.15% | 32.6σ | DIAGNOSE |
| cooling −40% on cell 12 | yes | ±7.31% | 5.5σ | DIAGNOSE |
| cooling −40% on cell 10 | no | ±32.4% | 1.2σ | REFUSE |
Cooling faults are identifiable on 4 of 32 cells - exactly the four carrying a thermocouple. The fault on cell 10 is really there; AstraCell declines to diagnose it.
The rest of the argument, each finding linked to its example, test, and figure in CLAIMS.md and derived in full in the report:
-
Refusal comes with a fix. A counterfactual thermocouple lifts cell 10's cooling SNR to 5.71σ (4.6× tighter) - or a 1.83C pulse does it with no new hardware. Excitation substitutes for a sensor. (
examples/03) -
Correlated noise reallocates information, it doesn't uniformly hurt: at
rho=0.99, capacity gets 10× worse whileR0andhAget better. This corrected a claim the repo once made the other way. (examples/02, WHAT_DID_NOT_WORK §2) -
The bound cannot see model bias. A first-order ECM fitted over 20 minutes manufactures an 18.5% capacity loss from a 5% fault - and more data makes it worse: reported confidence climbs to 14 611σ while credible confidence sits fixed at 6.49σ. (
examples/04) -
The verdicts are calibrated - and calibration makes them worse. Under mismatch the variance-only interval covers the truth 0% of the time; the model-bias gate drops harmful overclaim on capacity from 100% to 0%, by refusing. (
examples/05) -
An independently developed external simulator produces a phantom fault. Fitted to a healthy PyBaMM cell, the observer reports −67.6% ± 0.145% capacity loss (466σ from zero); a self-consistency control proves it is PyBaMM's physics, not our harness. The gate refuses. (
examples/06) -
The refusal discriminates. With a healthy baseline, the same machinery recovers a real injected fault at +20.0000% with nominal coverage, and still refuses a real degradation it cannot express - by a one-percent margin, reported not rounded away. (
examples/07) -
On real cells, it refuses - and it should. Run against all eight measured Oxford cells, each fading 20-38%, the first-order ECM's capacity estimate comes back wrong in sign - a phantom gain on seven of eight (+10.5% at Cell1's end of life against a −24.2% fade, ~1150σ from truth); AstraCell returns
REFUSE_MODEL_BIASon all 104 scored ages in both OCV modes (coverage 0/104, 208/208 evaluations). Neither a second-order observer (v0.8) nor fitting the fast RC branch - a 4-parameter(R0, Q, R1, C1)fit (v0.9) - moves that verdict: the branch is unidentifiable from a 1C discharge (VIF(R1) ≈ 287), so the pre-registered hope that it would de-confound is falsified. Eight-cell contact with a battery, and the honest outcome. (examples/08, REAL_CELL)
python -m venv .venv
.venv/Scripts/python -m pip install -e ".[dev,notebook]" # Windows
# .venv/bin/python -m pip install -e ".[dev,notebook]" # Linux / macOSor, with uv: uv venv && uv pip install -e ".[dev,notebook]".
| Command | What it does |
|---|---|
python examples/01_first_demo.py |
the whole thesis in one script; writes reports/figures/ |
python examples/02_noise_robustness.py |
relaxes the white-noise and known-current assumptions |
python examples/03_next_best_test.py |
ranks what to measure next; refuses when nothing suffices |
python examples/04_model_mismatch.py |
prices the observer's own model error |
python examples/05_calibrated_abstention.py |
are the verdicts calibrated across repeated trials? |
pip install -e ".[pybamm]" |
add the optional external simulator (PyBaMM) for examples 06-07 |
python examples/06_external_plant_gate.py |
does abstention survive an external simulator? |
python examples/07_external_positive_control.py |
and when that cell is really broken, does it notice? |
pip install -e ".[oxford]" · python scripts/fetch_oxford.py |
add the Oxford real-cell dataset (ODC-ODbL, ~254 MB licensed download) |
python examples/08_real_cell.py |
Tier 3: score the observer against a real cell's measured fade (skips without the data) |
python -m pytest |
256 tests, ~100 s (the real-cell test skips without the Oxford dataset; external-plant tests skip without PyBaMM) |
python -m ruff check src tests examples scripts · python -m mypy |
lint · type-check |
make check runs lint + format check + typecheck + test; make help lists every target. The full
pre-release sequence, the fresh-clone instructions, and the pinned-numbers guard are in
REPRODUCIBILITY.md.
duty cycle ──┐
pack params ─┼──▶ simulate() ──▶ central differences ──▶ S[t, cell, {V,T}, param]
fault inject ┘ │
sensor topology ──────────────────────────────────────────────── │ ← row mask
noise model ──────────────────────────────────────────────────── ▼
FIM = Sᵀ Σ⁻¹ S ──▶ CRLB = diag(FIM⁻¹)
│ │
VIF (isolation) ┤ ├ SNR = magnitude/√CRLB
▼ ▼
decide() ──▶ DIAGNOSE / WEAK_EVIDENCE
├─▶ REFUSE_UNOBSERVABLE + recommendation
├─▶ REFUSE_CONFOUNDED + recommendation
└─▶ REFUSE_MODEL_BIAS (bias ≫ signal)
Because sensitivities are computed for every cell's voltage and temperature, a sensor
topology is only a row mask over the sensitivity tensor - so counterfactual sensor
placement costs a matrix slice, not a re-simulation. Two gates run in order: isolation
(is the parameter separable? VIF > 10 ⇒ confounded) then detection (is the fault big
enough to clear the CRLB floor? ≥5σ / 2-5σ / <2σ). One detail worth stating: crlb()
does not use pinv - the pseudo-inverse returns finite variances for unidentified
parameters, which would make the system claim it can see things it cannot. Definitions of
every term are in GLOSSARY.md; the derivations in the
report's methods appendix.
src/astracell/
cell/ pack/ duty/ sensors/ first-order Thevenin + lumped thermal, 4x8 grid, duty cycles, AR(1) noise
faults/ physical faults vs sensor faults
observability/ sensitivity · fisher (FIM/CRLB/VIF) · mask · experiment · bias · estimator · decision
plant/ calibration/ richer plants (incl. PyBaMM) · Monte Carlo coverage, external, positive control
viz/ pack maps and heatmaps
examples/01..08 the thesis, then each honesty pass in turn
notebooks/01..04 generated by scripts/build_notebook.py, committed executed
docs/ TECHNICAL_REPORT · PORTFOLIO · CLAIMS · REPRODUCIBILITY · GLOSSARY ·
FIGURES · WHAT_DID_NOT_WORK · CALIBRATION · EXTERNAL_PLANT ·
POSITIVE_CONTROL · REAL_CELL
LIMITATIONS.md written before the code; now also a record of claims this repo got wrong
Each version added a harder credibility test; several made the headline result worse.
| Version | Question introduced | Outcome |
|---|---|---|
| v0.0 | Which faults are identifiable? | Fisher/CRLB machinery, grey-cell map, and explicit refusal |
| v0.1 | What if the observer model is wrong? | Structural-bias gate and REFUSE_MODEL_BIAS |
| v0.2 | Are the reported intervals calibrated? | Monte Carlo coverage showed variance-only confidence fails under mismatch |
| v0.3 | Does refusal survive independent physics? | PyBaMM produced a confidently wrong phantom fault; the gate refused it |
| v0.4 | Can the gate also accept a true positive? | A positive control exposed a broken statistic, then verified the corrected path |
| v0.5 | Can another engineer reproduce every claim? | Public package, evidence ledger, notebooks, and release gates |
| v0.6-0.7 | What happens on measured cells? | All eight Oxford cells exposed wrong-sign capacity estimates; 208/208 cases were refused |
| v0.8 | Is the refusal just a low-order-model artefact? | A second-order observer changed 0/208 verdicts |
| v0.9 | Does fitting the fast RC branch de-confound capacity? | Pre-registered H1 was falsified; the branch is itself unidentifiable from the discharge |
There is still no residual bank, classifier, dashboard, LLM, or validated real-cell fault detection result. Those come only after the observability and model-validity gates say the question is worth asking. See REAL_CELL.md for the measured-cell result and LIMITATIONS.md for the claims this work does not support.