Skip to content

Keep SiK gateways alive through CoT outages - #2

Merged
ampledata merged 1 commit into
mainfrom
fix/reconnect-supervisor
Aug 13, 2026
Merged

ampledata merged 1 commit into
mainfrom
fix/reconnect-supervisor

Conversation

@ampledata

Copy link
Copy Markdown
Contributor

The daemon, scan, and sentinel entry points construct custom CLITool worker graphs and therefore bypassed the standard PyTAK reconnect loop. Each now constructs a fresh client per attempt under the public PyTAK 7.5.2 supervisor. Transient CoT outages stay in-process with bounded backoff; local serial and configuration faults still reach systemd.

Validation: 7 tests pass locally, including all three entry-point reconnect wiring cases; flake8 and compileall pass on changed Python files.

@ampledata
ampledata merged commit de8c1ec into main Aug 13, 2026
16 checks passed
@ampledata
ampledata deleted the fix/reconnect-supervisor branch August 13, 2026 20:14